Climate tools icône

4.1 by CAREL INDUSTRIES S.p.A.


Nov 2, 2015

À propos de Climate tools

Français

L'application ultime pour la psychométrie d'air et le refroidissement par évaporation!

The ultimate app for air psychometrics and evaporative cooling!

What are the air characteristics given the current values of temperature and humidity? How can I calculate the mix of two air stream? What is the humidification load for my AHU? These are some of the questions this app can provide answers for, and, on top, also estimates of power saved by evaporative cooling.

There are 9 functions available inside the app:

· AIR calculates the characteristic parameters of the air by entering 2 of the following 4 values: dry-bulb temperature (DBT), wet-bulb temperature (WBT), %rh, humidity ratio. The outputs are: dew-point temperature, specific enthalpy, density, specific volume, vapor pressure, vapor density

· MIX calculates the characteristics of the mixture from the properties of two air streams (DBT, WBT, %rh, W, flow rate)

· HUMIDIFICATION LOAD 1 calculates the humidification load based on an air current upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification) and the conditions of pre-heating

· HUMIDIFICATION LOAD MIX calculates the humidification load from the mixture of 2 air streams upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification), the conditions of pre-heating, the characteristics of the mixture of the two air streams upstream of the humidifier

· DEC (Direct Evaporative Cooling) calculates the cooling, as temperature and as power, of an air stream by the evaporation of water sprayed in it

· IEC (Indirect Evaporative Cooling) calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed in a secondary air stream that does NOT mix with the primary stream. The primary and secondary streams pass through a cross-flow heat exchanger

· DEC + IEC calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed both in the primary stream and in a secondary air stream. The primary and secondary streams pass through a cross-flow heat exchanger WITHOUT mixing. The secondary stream is the exhausted part of the return air. If the exhaust flow is less than the primary flow, the part of return air not exhausted is mixed with the cooled primary air after the heat exchanger.

· EVAPORATIVE COOLING calculates the additional heat rejected by a condenser coil/dry cooler when they are sprayed by water, assuming that water completely wets the exposed surface of the heat-rejection coil.

· AFTER THE AIR HUMIDIFIER IN AHU/DUCT calculates the conditions downstream of the humidifier in AHU/duct once the environment’s set point and internal sensible and latent loads are entered.

Quoi de neuf dans la dernière version 4.1

Last updated on Nov 2, 2015

- new ebooks request form

Chargement de la traduction...

Informations Application supplémentaires

Dernière version

Demande Climate tools mise à jour 4.1

Telechargé par

Mù Ďì

Nécessite Android

Android 2.3.4+

Voir plus

Climate tools Captures d'écran

Charegement du commentaire...
Langues
Langues
Recherche en cours...
Abonnez-vous à APKPure
Soyez le premier à avoir accès à la sortie précoce, aux nouvelles et aux guides des meilleurs jeux et applications Android.
Non merci
S'inscrire
Abonné avec succès!
Vous êtes maintenant souscrit à APKPure.
Abonnez-vous à APKPure
Soyez le premier à avoir accès à la sortie précoce, aux nouvelles et aux guides des meilleurs jeux et applications Android.
Non merci
S'inscrire
Succès!
Vous êtes maintenant souscrit à notre newsletter.